Exclude paper white patches with IntellitraxCertain papers types can cause an incorrect reading of the leading paper white area on the sides of the colorbar.
The sample below shows a paper white patch at the end of the measured colorbar which should be excluded. There is a L threshold setup to exclude such patches on both sides of the colorbar.
Open the database with this link:
Go to the entry and change:
First_bad_patches_L_min
First_bad_patches_L_max
|